The automatic dosing machine needs to be frequently tested and maintained by maintenance staff who are familiar with its structure and characteristics to ensure the safety, reliability and long-term operation of the dosing machine. Below, I will talk about the precautions for daily maintenance and maintenance.
1. First, add oil to the motor bearings, intermediate bearings and transmission before starting. Add 2% calcium lithium grease to the motor bearings and intermediate bearings, add 30% mechanical oil to the transmission, and add the oil level to the core of the oil cup. .
2. The motor bearings and intermediate bearings of the automatic dosing machine should be replaced with lubricating oil every half a year of operation. If the transmission oil is found to be short of oil in the oil cup, add lubricating oil in time. Every half a year of operation, all the oil in the transmission must be poured out. Change the lubricating oil again.
3. Every one year of operation of the transmission, it is necessary to pour out all the lubricating oil in the transmission and clean the transmission with cleaning agent. At the same time, check whether the gears in the transmission are seriously damaged and damaged. If necessary, replace them. Gear or transmission.